187
The
BEEP statement does not suspend execution of the subsequent statement
until the beeper completes sounding or vibrating. Instead, the execution of the
subsequent statement proceeds immediately.
If a second
BEEP statement is encountered while the BHT is still beeping or
vibrating by a first
BEEP, the first BEEP is cancelled and the new BEEP statement
executes.
In the BHT-3000, if the beeper starts sounding for warning you of the low battery
during beeping programmed by the
BEEP, then the warning beep overrides the
programmed beeping.
In the BHT-6000/BHT-6500/BHT-7000/BHT-7500 also, if low battery warning
operation starts during beeping or vibrating programmed by the
BEEP, then the
warning operation overrides the programmed beeping or vibrating. Upon comple-
tion of the warning operation, the beeper or vibrator resumes working as pro-
grammed.
Syntax errors:
Run-time errors:
Example:
BEEP bon%,boff%,count%,helz%
BEEP bon%,boff%,count%
BEEP bon%,boff%,,helz%
BEEP bon%,,count%,helz%
BEEP ,boff%,count%,helz%
BEEP bon%,boff%
BEEP bon%,,count%
BEEP ,boff%,count%
BEEP bon%,,,helz%
BEEP ,boff%,,helz%
BEEP ,,count%,helz%
BEEP bon%
BEEP ,boff%
BEEP ,,count%
BEEP ,,,helz%
BEEP
Error code and message Meaning
error 71: Syntax error
The number of parameters or commas
(,) exceeds the limit.
Error code Meaning
05h
Parameter out of the range