Chapter 15. Function Reference
359
Syntax:
FRE(areaspec)
Parameter:
areaspec
A numeric expression which returns a value from 0 to 3.
Description:
FRE returns the number of bytes left unused in a memory area specified by
areaspec listed below.
The file area will be allocated to data files and program files in cluster units. The
FRE function returns the total number of bytes of non-allocated clusters. (For
details about a cluster, refer to Appendix F, "Memory Area.")
The operation stack area for the Interpreter is mainly used for numeric operations,
string operations, and for calling user-defined functions.
A returned value of this function is a decimal number.
Run-time errors:
FREe area Memory management function
FRE
Returns the number of bytes available in a specified area of the memory.
areaspec
Memory area
0
Array work variable area
1
File area
2
Operation stack area for the Interpreter
3
File area in drive B (in the BHT-5000/BHT-6000/BHT-6500)
Error code Meaning
05h
Parameter out of the range
(
areaspec is out of the range.)