Denso RC5 Dokumentacja Strona 63

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 138
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 62
51
8.5 Field Network Error Indication (Version 1.5 or later)
In Main Software Version 1.5 or later, the "10: FieldNetwork ErrDisplay" parameter is
newly added to the I/O Hardware Settings window (Access: [F4 I/O]—[F6 Aux.]—[F1
Set H/W]). This parameter allows you to choose whether a network error will display
"every time" it occurs or at the "first time."
This parameter takes effect in the DeviceNet masters and slaves and the PROFIBUS
slaves.
The addition of this parameter disables the "8: DeviceNet Setup ErrDisplay" in the I/O
Hardware Settings window.
This parameter is set to "0" (EveryTime) by default for safe operation of the facilities.
Every time an I/O operation is carried out, an error will display if any.
To check program operations using dummy I/Os for setting up facilities where no
connection to the network has been established, set this parameter to "1" (First
Time). Doing so will not display errors once detected, allowing you to check program
operations.
NOTE: After completion of setting-up, be sure to set this parameter back to
"0."
n Changing the FieldNetwork ErrDisplay parameter
Access: [F4 I/O]—[F6 Aux.]—[F1 Set H/W]
Step 1
Press [F1 Set H/W] in the Auxiliary Function (I/O) window.
F1
Przeglądanie stron 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 137 138

Komentarze do niniejszej Instrukcji

Brak uwag