Chapter 4 Specifications of the Robot Controller
43
RC7M Controller Specifications (2) (HS-G series)
Item Specifications
Environmental conditions
(in operation)
Temperature: 0 to 40C
Humidity: 90% RH or less (no condensation allowed)
Power source
Three-phase, 200 VAC-15% to 230 VAC+10%, 50/60 Hz, 1.8 kVA
Single-phase, 230 VAC-10 to 230 VAC+10%, 50/60 Hz, 1.8 kVA
Degree of protection
IP20
Weight
Standard type: Approx. 17 kg (38 lbs)
Global type with safety board: Approx. 18 kg (40 lbs)
Global type with safety box: Approx. 21 kg (46 lbs)
WARNING
DO NOT touch fins. Their hot surfaces may cause severe
burns.
DO NOT insert fingers or foreign objects into openings.
Doing so may cause bodily injury.
Before opening the controller cover and accessing the inside
of the controller for maintenance, be sure to turn off the
power switch, disconnect the power cable, and wait 3
minutes or more. This is for protecting you from electric
shock.
DO NOT connect or disconnect connector to/from the
controller while the power switch is on. Doing so may cause
electric shock or controller failure.
CAUTION IN INSTALLATION
This controller is not designed to be dust-proof,
splash-proof, or explosion-proof.
Read operation-manuals before installation.
Do not place anything on the controller.