Denso RC5 Dokumentacja Strona 670

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 692
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 669
22-18
No. Items
Factory
default
Powering-on
default
Description Comments
92 Force limit rate (+RX)
(For 6-axis robot)
10000 10000 Force control rate around the +X axis
under compliance control
93
Force limit rate (+RY)
(For 6-axis robot)
10000 10000
Force control rate around the +Y axis
under compliance control
94 Force limit rate (+RZ)
(For 6-axis robot)
10000 10000 Force control rate around the +Z axis
under compliance control
Can be set with
SetFrcCoord.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
95
Force limit rate (-X)
(For 6-axis robot)
10000 10000
Force control rate along the -X axis
under compliance control
96 Force limit rate (-Y)
(For 6-axis robot)
10000 10000 Force control rate along the -Y axis
under compliance control
97
Force limit rate (-Z)
(For 6-axis robot)
10000 10000
Force control rate along the -Z axis
under compliance control
Can be set with
SetFrcCoord.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
98 Force limit rate (-RX)
(For 6-axis robot)
10000 10000 Force control rate around the -X axis
under compliance control
99
Force limit rate (-RY)
(For 6-axis robot)
10000 10000
Force control rate around the -Y axis
under compliance control
100 Force limit rate (-RZ)
(For 6-axis robot)
10000 10000 Force control rate around the -Z axis
under compliance control
Can be set with
SetFrcCoord.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
101
Compliance setting
rate (X)
(For 6-axis robot)
10000 10000
Compliance rate along the X-axis under
compliance control
102
Compliance setting
rate (Y)
(For 6-axis robot)
10000 10000
Compliance rate along the Y-axis under
compliance control
103 Compliance setting
rate (Z)
(For 6-axis robot)
10000 10000 Compliance rate along the Z-axis under
compliance control
Can be set with
SetCompRate.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
104 Compliance setting
rate (RX)
(For 6-axis robot)
10000 10000 Compliance rate around the X-axis
under compliance control
105 Compliance setting
rate (RY)
(For 6-axis robot)
10000 10000 Compliance rate around the Y-axis
under compliance control
106 Compliance setting
rate (RZ)
(For 6-axis robot)
10000 10000 Compliance rate around the Z-axis
under compliance control
Can be set with
SetCompRate.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
107
Compliance/positional
error allowance (X)
(For 6-axis robot)
100 100
Allowable deviation along the X-axis
under compliance control
108
Compliance/positional
error allowance (Y)
(For 6-axis robot)
100 100
Allowable deviation along the Y-axis
under compliance control
109 Compliance/positional
error allowance (Z)
(For 6-axis robot)
100 100 Allowable deviation along the Z-axis
under compliance control
Can be set with
SetCompEralw.
Cannot be
modified with the
teach pendant.
(Ver. 1.4 or later)
Przeglądanie stron 669
1 2 ... 665 666 667 668 669 670 671 672 673 674 675 ... 691 692

Komentarze do niniejszej Instrukcji

Brak uwag