Parameter name Macro name Description
RS232C(2). Communication priority COM_RS2_ACCESS
Communication priority setting of RS232C channel 2 of the
controller (0: not available, 1: only reading, 2: read/write available)
RS232C(2). Baud rate COM_RS2_SPEED Baud rate setting of RS232C channel 2 of the controller (unit: bps)
RS232C(2). Parity
(0: even, 1: non, 2: odd)
COM_RS2_PARITY Parity setting of RS232C channel 2 of the controller
(0: even, 1: non, 2: odd)
RS232C(2). Data length COM_RS2_DATELEN Data length setting of RS232C channel 2 of the controller (unit: bit)
RS232C(2). Stop bit
(0: 1bit, 1: 1.5bit, 2: 2bit)
COM_RS2_STOPBIT Stop bit setting of RS232C channel 2 of the controller
(0: 1bit, 1: 1.5bit, 2: 2bit)
RS232C(2). Delimiter
(0: CR, 1: CR + LF)
COM_RS2_DELIMITER Delimiter setting of RS232C channel 2 of the controller
(0: CR, 1: CR + LF)
RS232C(3). Communication priority COM_RS3_ACCESS Communication priority setting of RS232C channel 3 of the
controller (0: not available, 1: only reading, 2: read/write available)
RS232C(3). Baud rate COM_RS3_SPEED Baud rate setting of RS232C channel 3 of the controller (unit: bps)
RS232C(3). Parity
(0: even, 1: non, 2: odd)
COM_RS3_PARITY Parity setting of RS232C channel 3 of the controller
(0: even, 1: non, 2: odd)
RS232C(3). Data length COM_RS3_DATELEN Data length setting of RS232C channel 3 of the controller (unit: bit)
RS232C(3). Stop bit
(0: 1bit, 2: 1.5bit, 3: 2bit)
COM_RS3_STOPBIT
Stop bit setting of RS232C channel 3 of the controller
(0: 1bit, 1: 1.5bit, 2: 2bit)
RS232C(3). Delimiter
(0: CR, 1: CR + LF)
COM_RS3_DELIMITER
Delimiter setting of RS232C channel 3 of the controller
(0: CR, 1: CR + LF)
RS232C(4). Communication priority COM_RS4_ACCESS Communication priority setting of RS232C channel 4 of the
controller
(0: not available, 1: only reading, 2: read/write available)
RS232C(4). Baud rate COM_RS4_SPEED Baud rate setting of RS232C channel 4 of the controller (unit: bps)
RS232C(4). Parity
(0: even, 1: non, 2: odd)
COM_RS4_PARITY Parity setting of RS232C channel 4 of the controller
(0: even, 1: non, 2: odd)
RS232C(4). Data length COM_RS4_DATELEN Data length setting of RS232C channel 4 of the controller (unit: bit)
RS232C(4). Stop bit
(0: 1bit, 1: 1.5bit, 2: 2bit)
COM_RS4_STOPBIT Stop bit setting of RS232C channel 4 of the controller
(0: 1bit, 1: 1.5bit, 2: 2bit)
RS232C(4). Delimiter
(0: CR, 1: CR + LF)
COM_RS4_DELIMITER Delimiter setting of RS232C channel 4 of the controller
(0: CR, 1: CR + LF)
Ethernet. Communication priority COM_ET_ACCESS Controller Ethernet communication setting
(0: not available, 1: only reading, 2: read/write available)
Ethernet. IP address COM_ET_IP_ADDR Controller Ethernet IP address setting
Ethernet. Sub net mask COM_ET_SUBNET_MASK Controller Ethernet sub net mask setting
Ethernet. connection destination 1. local port COM_ET_LPORT1 Connection destination of the controller Ethernet 1.local port setting
Ethernet. connection destination 2. local port COM_ET_LPORT2 Connection destination of the controller Ethernet 2.local port setting
Ethernet. connection destination 3. local port COM_ET_LPORT3 Connection destination of the controller Ethernet 3.local port setting
Ethernet. connection destination 4. local port COM_ET_LPORT4 Connection destination of the controller Ethernet 4.local port setting
Ethernet. connection destination 5. local port COM_ET_LPORT5 Connection destination of the controller Ethernet 5.local port setting